This equipment is dedicated to the integrated performance testing of brushless DC vacuum cleaner motors, and can simultaneously calculate parameters such as air flow and efficiency based on the test data.
| Test Item | Measured Parameter | Specification / Value |
|---|---|---|
| Voltage Test | Measured Parameter | AC/DC Voltage |
| Measuring Range | 500 V | |
| Resolution | 0.1 V | |
| Accuracy | Class 0.5 | |
| Current Test | Measured Parameter | AC/DC Current |
| Measuring Range | 15 A | |
| Resolution | 0.001 A | |
| Accuracy | Class 0.5 | |
| Negative Pressure Test | Measuring Range | -0.1~100 MPa |
| Pressure Type | Gauge pressure (default), Absolute pressure | |
| Accuracy Class | 0.2%FS / 0.1%FS | |
| Overload Capacity | ≤1.5 times | |
| Mechanical Vibration | 20G (20~5 KHz) | |
| Compensation Temperature | -10~70 ℃ | |
| Zero Temperature Drift | 0.5%FS (MAX) | |
| Sensitivity Temperature Drift | 0.5%FS (MAX) | |
| Sampling Rate | 20 times/second | |
| Long-term Stability | ≤0.2%FS/year | |
| Vibration Test (1~3 channels, optional) |
Sensitivity (20±5℃) | 100 mV/g |
| Measuring Range (Peak) | 50 g | |
| Maximum Transverse Sensitivity | ≤5 % | |
| Frequency Response (±5%) | 1~5000 Hz | |
| Operating Temperature Range | -40~+150 ℃ | |
| Temperature Response | See temperature curve | |
| Base Isolation | >109 Ω | |
| Mounting | M5 |
The equipment is specifically engineered for testing the comprehensive performance of brushless DC motors used in vacuum cleaners, evaluating electrical, mechanical, and pneumatic characteristics.
In addition to standard voltage, current, and pressure measurements, the machine automatically calculates derived performance parameters such as air flow rate and motor operating efficiency based on collected real-time data.
Yes, the embedded testing software fully supports MES data uploading, localized data storage, and direct report printing for unified industrial data management.
The double-station model allows for rapid wiring and simultaneous dual-motor testing, substantially increasing measurement throughput, reducing cycle times, and improving production line efficiency.
The negative pressure testing module covers a range of -0.1 to 100 MPa with a high accuracy class of 0.2%FS / 0.1%FS and a sampling rate of up to 20 times per second.
Vibration testing (1 to 3 channels) is available as an optional feature, allowing custom configurations based on specific inspection and quality assurance requirements.